@@ -836,13 +836,14 @@ by hand if you are a Python expert. Otherwise you can just read the values.
|
||||
<br>
|
||||
To create a Receive correction point for a given VFO and frequency, attach a signal generator to the SoftRock through an attenuator,
|
||||
and look at the image on the graph screen. If the signal is 3500 Hertz above the VFO, the image is 3500 Hertz below it.
|
||||
If you don't have a signal generator, find a strong station on the band and look at its image. Minimize the image by adjusting
|
||||
the amplitude and phase sliders on the adjustment screen, and then press "Save".
|
||||
Choose "Measure" to measure the corrections and then "Add Cell".
|
||||
If you don't have a signal generator, find a strong station on the band and look at its image. Choose "Manual adjustment".
|
||||
Minimize the image by adjusting the amplitude and phase sliders on the adjustment screen, and then press "Add cell".
|
||||
<br>
|
||||
<br>
|
||||
To create a Transmit correction point for a given VFO and frequency, attach the SoftRock RF output to a spectrum analyzer through an attenuator,
|
||||
and look at the image. If you don't have a spectrum analyzer use a second receiver tuned to the image. Minimize the image by adjusting
|
||||
the amplitude and phase sliders on the adjustment screen, and then press "Save".
|
||||
the amplitude and phase sliders on the adjustment screen, and then press "Add cell".
|
||||