Quisk version 4.2.49

This commit is contained in:
James C. Ahlstrom
2025-12-22 15:12:47 -05:00
parent 1111d24333
commit 018fc0e871
10 changed files with 285 additions and 68 deletions
+37
View File
@@ -488,6 +488,7 @@ power_meter_std_calibrations['HL2FilterE3'] = [[ 0, 0.0 ], [ 25.865384615384617,
[ 4093.1785714285716, 7.28994845808807 ], [ 4502.496428571429, 8.820837634286566 ], [ 4952.746071428572, 10.673213537486745 ] ]
#power_meter_std_calibrations['HL2FilterE1'] = [[0, 0.0], [9.07, 0.002], [54.98, 0.014], [148.6, 0.057],
# [328.0, 0.208], [611.1, 0.646], [807.0, 1.098], [982.1, 1.6], [1223.3, 2.471], [1517.7, 3.738], [1758.7, 5.02]]
power_meter_std_calibrations['Show ADC'] = []
## Hermes_BandDict Rx IO Bus, dict
# The Hermes_BandDict sets the 7 bits on the J16 connector for Rx.
@@ -662,6 +663,42 @@ Hermes_BandDictTx = {'160':0, '80':0, '60':0, '40':0, '30':0, '20':0, '17':0, '1
Hermes_BandDictEnTx = False
#Hermes_BandDictEnTx = True
## calibrate_temp_20 PA temp ADC at 20\u2103, integer
# This is the ADC code returned for a temperature of 20C.
# To see the ADC code being returned, enter zero for both temperature codes.
# Linear interpolation is used to calculate the temperature.
# Changes are immediate (no need to restart).
calibrate_temp_20 = 0
## calibrate_temp_40 PA temp ADC at 40\u2103, integer
# This is the ADC code returned for a temperature of 40C.
# To see the ADC code being returned, enter zero for both temperature codes.
# Linear interpolation is used to calculate the temperature.
# Changes are immediate (no need to restart).
calibrate_temp_40 = 0
## calibrate_current_0 PA current ADC at zero, integer
# This is the ADC code returned for a PA current of zero.
# To see the ADC code being returned, enter zero for both current codes.
# Linear interpolation is used to calculate the current.
# Changes are immediate (no need to restart).
calibrate_current_0 = 0
## calibrate_current_1 PA current ADC at 1 amp, integer
# This is the ADC code returned for a PA current of one amp.
# To see the ADC code being returned, enter zero for both current codes.
# Linear interpolation is used to calculate the current.
# Changes are immediate (no need to restart).
calibrate_current_1 = 0
## power_meter_calib_name Power meter calibration, text choice
# This is the calibration table used to convert the power sensor voltage measured by the ADC to the transmit power display.
# It is a table of ADC codes and the corresponding measured power level. If you have a power meter, you can create your own
# table by selecting "New". Then enter ten or more power measurements from low to full power.
# For the Hermes Lite2 version E3 filter board, use the built-in table "HL2FilterE3".
# Changes are immediate (no need to restart).
power_meter_calib_name = 'HL2FilterE3'
################ Receivers SoapySDR, The SoapySDR interface to multiple SDRs.