Quisk version 4.2.49
This commit is contained in:
@@ -488,6 +488,7 @@ power_meter_std_calibrations['HL2FilterE3'] = [[ 0, 0.0 ], [ 25.865384615384617,
|
||||
[ 4093.1785714285716, 7.28994845808807 ], [ 4502.496428571429, 8.820837634286566 ], [ 4952.746071428572, 10.673213537486745 ] ]
|
||||
#power_meter_std_calibrations['HL2FilterE1'] = [[0, 0.0], [9.07, 0.002], [54.98, 0.014], [148.6, 0.057],
|
||||
# [328.0, 0.208], [611.1, 0.646], [807.0, 1.098], [982.1, 1.6], [1223.3, 2.471], [1517.7, 3.738], [1758.7, 5.02]]
|
||||
power_meter_std_calibrations['Show ADC'] = []
|
||||
|
||||
## Hermes_BandDict Rx IO Bus, dict
|
||||
# The Hermes_BandDict sets the 7 bits on the J16 connector for Rx.
|
||||
@@ -662,6 +663,42 @@ Hermes_BandDictTx = {'160':0, '80':0, '60':0, '40':0, '30':0, '20':0, '17':0, '1
|
||||
Hermes_BandDictEnTx = False
|
||||
#Hermes_BandDictEnTx = True
|
||||
|
||||
## calibrate_temp_20 PA temp ADC at 20\u2103, integer
|
||||
# This is the ADC code returned for a temperature of 20C.
|
||||
# To see the ADC code being returned, enter zero for both temperature codes.
|
||||
# Linear interpolation is used to calculate the temperature.
|
||||
# Changes are immediate (no need to restart).
|
||||
calibrate_temp_20 = 0
|
||||
|
||||
## calibrate_temp_40 PA temp ADC at 40\u2103, integer
|
||||
# This is the ADC code returned for a temperature of 40C.
|
||||
# To see the ADC code being returned, enter zero for both temperature codes.
|
||||
# Linear interpolation is used to calculate the temperature.
|
||||
# Changes are immediate (no need to restart).
|
||||
calibrate_temp_40 = 0
|
||||
|
||||
## calibrate_current_0 PA current ADC at zero, integer
|
||||
# This is the ADC code returned for a PA current of zero.
|
||||
# To see the ADC code being returned, enter zero for both current codes.
|
||||
# Linear interpolation is used to calculate the current.
|
||||
# Changes are immediate (no need to restart).
|
||||
calibrate_current_0 = 0
|
||||
|
||||
## calibrate_current_1 PA current ADC at 1 amp, integer
|
||||
# This is the ADC code returned for a PA current of one amp.
|
||||
# To see the ADC code being returned, enter zero for both current codes.
|
||||
# Linear interpolation is used to calculate the current.
|
||||
# Changes are immediate (no need to restart).
|
||||
calibrate_current_1 = 0
|
||||
|
||||
## power_meter_calib_name Power meter calibration, text choice
|
||||
# This is the calibration table used to convert the power sensor voltage measured by the ADC to the transmit power display.
|
||||
# It is a table of ADC codes and the corresponding measured power level. If you have a power meter, you can create your own
|
||||
# table by selecting "New". Then enter ten or more power measurements from low to full power.
|
||||
# For the Hermes Lite2 version E3 filter board, use the built-in table "HL2FilterE3".
|
||||
# Changes are immediate (no need to restart).
|
||||
power_meter_calib_name = 'HL2FilterE3'
|
||||
|
||||
|
||||
################ Receivers SoapySDR, The SoapySDR interface to multiple SDRs.
|
||||
## hardware_file_name Hardware file path, rfile
|
||||
|
||||
Reference in New Issue